Analisa Pengaruh Jenis Refrigrant Terhadap Laju Pengeringan Pakaian Dengan Menggunakan Energi Panas Buangan Kondensor Air Conditioner

Authors

  • Arif Mulyanto universitas mataram
  • I.M. Nuarsa Universitas Mataram
  • M Pauzi Putra Universitas Mataram

Abstract

Until now, air conditioner (AC) just used to control air for human comfort. There is energy wasted from the condenser which can be used as a heat source for clothes dryer. The reseacrh is conducted to determine the refrigerant which has the best performance for the clothes dryer. Three types of refrigerants, R-22,  R-32,  and  R-410a, are used as coolants in air conditioner. 15 spinner-dried wet clothes were used as the drying load. Hot air exits the condenser drying the wet shirt. The highest drying rate  gained when using R-32, 0.022 kg/min  with 60 minutes of drying time  and 23.02% efficiency.  while R-40, 0,022 kg/min drying rate, with 60 minutes of drying time and 24,74 efficiency. While the highest efficiency obtained by  R-22,  35.70%, with 0.018  kg/min  of drying rate and  75 minutes of drying  time.

Author Biographies

Arif Mulyanto, universitas mataram

Teknik Mesin Universits mataram

I.M. Nuarsa, Universitas Mataram

Teknik mesin Universitas mataram

M Pauzi Putra, Universitas Mataram

Teknik mesin Universitas mataram

References

Ameen, A., and Saiful Bari, 2004, Investigation Into The Effectivenes Of Heat Pump Assisted Clothes Dryer For Humid Tropic, Energi Conversion And Management, pp. 137-1405.

Hermawan, I., Iswandi Idris, 2014, Kajian Potensi Energi Panas Buangan Dari Air Conditioner (AC), Jurnal Teknovasi, Volume 01, No 02, Hal 1-7.

Mahlia., T.M.I., H.H. Masjuki, M. Husnawan, M. Varman, S. Mekhilef, 2010, Clothes Drying From Room Air Conditioning Waste Heat : Thermodynamics Investigation, The Arabian Jurnal For Science And Engineering, Volume35, Number 1B, 339-351.

Nesri, T.V., Azridjal, A., Rahmat, I.M., 2016, Karakteristik Mesin Pengering Pakaian Menggunakan Ac (Air Conditioner) Dengan Siklus Kompresi Uap Sistem Udara Terbuka, Jurnal Sains Dan Teknologi, Volume 02, Hal 63-68.

Nugroho, D.A.C., 2018, Mesin Pengering Pakaian Sistem Udara Terbuka Dengan Menggunakan Komponen AC Split Dengan Satu Kipas Dan Tanpa Kipas, Skripsi, Universitas Sanata Dharma, Yogyakarta.

Panggabean, T., Arjuna Neni Triana, Ari Hayati, 2017, Kinerja Pengeringan Gabah Menggunakan Alat Pengering Tipe Rak Dengan Energi Surya, Biomassa, dan Kombinasi, Jurnal Ilmiah Agritech, Volume 37, No 2, Hal 229-235.

Purwadi, PK., 2017, Mesin Pengering Kapasitas Lima Puluh Baju Sistem Tertutup, Jurnal Ilmiah Widya Teknik, Volume 16, No 2 2017.

Suarnadwipa, N., Bandem, I.W.B., 2017, Potensi Pemanfaatan Energi Buangan Kondensor Untuk Pengeringan Pakaian, Seminar Nasional Sains Dan Teknologi, SENASTEK IV, Vol. 2507, No. 1- 2.

Downloads

Published

2022-10-24